SLVSIA7 March 2025 TPSI3050M
PRODUCTION DATA
Table 7-3 summarizes the functional modes for the TPSI3050M.
| VDDP(6) | VDDH | EN(6) | VDRV | COMMENTS |
|---|---|---|---|---|
| Powered up(2) | Powered up(4) | L | L | TPSI3050M normal operation: VDRV output state assumes logic state of EN logic state. |
| H | H | |||
| Powered down(3) | Powered down(5) | X(1) | L | Disabled operation: VDRV output disabled, keep off circuitry applied. |
| Powered up(2) | Powered down(5) | X(1) | L | Disabled operation: VDRV output disabled, keep off circuitry applied. |