SLVSJC6 December 2025 TPS544B27W
PRODUCTION DATA
The TPS544B27W provides forced continuous conduction mode (FCCM) operation for low output ripple at light-load or discontinuous conduction mode (DCM) with auto-skipping Eco-mode for improved light-load efficiency. The switching frequency and operation mode can be programmed through the PMBus interface using the PMBus (33h) FREQUENCY_SWITCH command and FCCM bit in the PMBus (D0h) SYS_CFG_USER1 command. Changes to PMBus (33h) FREQUENCY_SWITCH take effect immediately, even if the output is enabled. Changes to the FCCM bit do not take effect until the output is disabled through the PMBus (02h) ON_OFF_CONFIG mechanism.