SLVSJC6 December 2025 TPS544B27W
PRODUCTION DATA
| PARAMETER | MIN | NOM | MAX | UNIT | |
|---|---|---|---|---|---|
| PMBUS INTERFACE | |||||
| fPMB_CLK | PMBus operating frequency range | 10 | 1000 | kHz | |
| tBUF | Bus free time between a STOP and START condition (1) | 0.5 | µs | ||
| tHD_STA | Hold time for a (repeated) START condition (1) | 0.26 | µs | ||
| tSU_STA | Setup time for a repeated START condition (1) | 0.26 | µs | ||
| tSU_STO | Setup time for a STOP condition (1) | 0.26 | µs | ||
| tHD_PMB | PMB_DATA hold time (1) | 0 | µs | ||
| tSU_PMB | PMB_DATA setup time (1) | 50 | ns | ||
| tLOW | Low period of PMB_CLK (1) | 0.5 | µs | ||
| tHIGH | High period of PMB_CLK (1) | 0.26 | 50 | µs | |
| tR_PMB | PMB_CLK and PMB_DATA rise time with fPMB_CLK = 100kHz (1)(2) | 1000 | ns | ||
| PMB_CLK and PMB_DATA rise time with fPMB_CLK = 400kHz (1)(2) | 300 | ns | |||
| PMB_CLK and PMB_DATA rise time with fPMB_CLK = 1MHz (1)(2) | 120 | ns | |||
| tF_PMB | PMB_CLK and PMB_DATA fall time with fPMB_CLK = 100kHz or 400kHz (1)(3) | 300 | ns | ||
| PMB_CLK and PMB_DATA fall time with fPMB_CLK = 1MHz (1)(3) | 120 | ns | |||