SLVT251 July   2026

 

  1.   1
  2.   Description
  3.   Resources
  4.   Features
  5.   Applications
  6.   6
  7. 1System Description
    1. 1.1 Key System Specifications
  8. 2System Overview
    1. 2.1 Block Diagram
    2. 2.2 Design Considerations
      1. 2.2.1 High-Voltage Stackable Architecture
      2. 2.2.2 Electrochemical Impedance Spectroscopy (EIS) Subsystem
      3. 2.2.3 EIS Synchronization Requirement
      4. 2.2.4 PWM Input as Crystal of the First BQ79826Z-Q1
      5. 2.2.5 Temperature Sensing and Multiplexer Network
      6. 2.2.6 Cell Balancing Circuit and Operation
      7. 2.2.7 MCU and System Control Architecture
      8. 2.2.8 Protection and On-Board Diagnostics
    3. 2.3 Highlighted Products
      1. 2.3.1 BQ79826Z-Q1
      2. 2.3.2 TMUX1308
      3. 2.3.3 TMP61
      4. 2.3.4 SN74LXC1T14
  9. 3Hardware, Software, Testing Requirements, and Test Results
    1. 3.1 Hardware Requirements
    2. 3.2 Software
    3. 3.3 Test Setup
    4. 3.4 Pack Test Results
      1. 3.4.1 Cell Voltage Reliability Test
      2. 3.4.2 EIS Measurement Repeatability
      3. 3.4.3 Pack EIS Measurement Nyquist Plot
      4. 3.4.4 Current Consumption per BQ79826Z-Q1
  10. 4Design and Documentation Support
    1. 4.1 Design Files
      1. 4.1.1 Schematics
      2. 4.1.2 BOM
      3. 4.1.3 PCB Layout Recommendations
    2. 4.2 Tools and Software
      1. 4.2.1 Tools
    3. 4.3 Documentation Support
    4. 4.4 Support Resources
    5.     Trademarks
  11. 5About the Author

System Description

Battery energy storage systems (BESS) continue rapid growth in residential, commercial, industrial, and grid-scale deployment. The industry is clearly trending toward 1500V high-voltage platforms, large-capacity 500Ah+ cells, and 104s high-series battery pack architectures. Large-format Li-ion and LiFePO4 cells improve system energy density, reduce overall BOM and installation cost, and support long-duration energy storage scenarios, while also bringing new safety and monitoring challenges to conventional BMS designs.

Traditional battery management systems rely only on cell voltage and surface temperature sampling for protection and state estimation. However, large-capacity cells feature high thermal inertia and obvious time delay between internal electrochemical reaction and external temperature rise. Conventional temperature sensors only trigger alarms in the late stage of thermal runaway, resulting in extremely short response windows for system mitigation. In addition, traditional SOC and SOH algorithms lack internal electrochemical characteristic data, leading to low estimation accuracy under dynamic charge-discharge conditions.

To address these industry pain points, the TIDA-010978 reference design is developed as a next-generation stackable BMU integrated with native EIS capability. This design adopts BQ79826ZQ1 as the core 26S battery monitor, supporting 52S per board and cascading to 104S for 1500V ESS applications.

Different from conventional BMU designs, TIDA-010978 integrates pack-level EIS measurement without adding extra excitation hardware, by reusing the active pack balancing power stage (TIDA-010990). TIDA-010978 realizes high accuracy of impedance measurement. Meanwhile, the design retains complete standard BMU functions including high-accuracy cell monitoring, full temperature coverage via multiplexer expansion, passive cell balancing, isolated daisy-chain stacking, and CAN FD communication.

This reference design fully complies with UL1973, IEC 62477, and GB 38031 safety regulations, providing complete hardware schematic, PCB layout, firmware framework, GUI upper computer, and test validation reports for high-voltage large-capacity energy storage developers.