SPRUIW9C October 2021 – March 2024 TMS320F280033 , TMS320F280034 , TMS320F280034-Q1 , TMS320F280036-Q1 , TMS320F280036C-Q1 , TMS320F280037 , TMS320F280037-Q1 , TMS320F280037C , TMS320F280037C-Q1 , TMS320F280038-Q1 , TMS320F280038C-Q1 , TMS320F280039 , TMS320F280039-Q1 , TMS320F280039C , TMS320F280039C-Q1
The time-base counter operates in one of four modes:
To illustrate the operation of the first three modes, the following timing diagrams show when events are generated and how the time-base responds to an EPWMxSYNCI signal.
Figure 20-9 Time-Base
Up-Count Mode Waveforms
Figure 20-10 Time-Base
Down-Count Mode Waveforms
Figure 20-11 Time-Base
Up-Down-Count Waveforms, TBCTL[PHSDIR = 0] Count Down On Synchronization Event
Figure 20-12 Time-Base Up-Down
Count Waveforms, TBCTL[PHSDIR = 1] Count Up On Synchronization Event