DLP4500NIR
Digitaler DLP®-Mikrospiegelbaustein (DMD), 0,45 Zoll, WXGA NIR
DLP4500NIR
- 0.45-Inch Diagonal Micromirror Array
- 912 × 1140 Resolution Array (>1 Million Micromirrors)
- Diamond Array Orientation Supports Side Illumination for Simplified, Efficient Optics Designs
- Capable of WXGA Resolution Display
- 7.6-µm Micromirror Pitch
- ±12° Tilt Angle
- 5-µs Micromirror Crossover Time (Nominal)
- Highly Efficient Steering of NIR Light
- Window Transmission Efficiency 96% Nominal ( 700 to 2000 nm, Single Pass Through Two Window Surfaces)
- Window Transmission Efficiency 90% Nominal (2000 to 2500 nm, Single Pass Through Two Window Surfaces)
- Polarization-Independent Aluminum Micromirrors
- Array Fill Factor 92% (Nominal)
- Dedicated DLPC350 Controller for Reliable Operation
- Binary Pattern Rates Up to 4 kHz
- Pattern Sequence Mode for Control Over Each Micromirror in Array
- Integrated Micromirror Driver Circuitry
- 9.1-mm × 20.7-mm for Portable Instruments
- FQD Package With Enhanced Thermal Interface
The DLP4500 NIR digital micromirror device (DMD) acts as a spatial light modulator (SLM) to steer near-infrared (NIR) light and create patterns with speed, precision, and efficiency. Featuring high resolution in a compact form factor, the DLP4500 NIR DMD is often combined with a single element detector to replace expensive InGaAs array-based detector designs, leading to high performance, cost-effective portable solutions.
Weitere Informationen anfordern
Für die weitere Entwicklung benötigen Sie ein optisches Modul. Sehen Sie sich das Suchtool für optische Module an, um ein optisches Modul auszuwählen, welches mit Ihrem DMD kompatibel ist. Weitere Informationen
Technische Dokumentation
Design und Entwicklung
Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.
DLPNIRSCANEVM — DLP® NIRscan™-Evaluierungsmodul
Das DLP NIRscan ist ein komplettes Evaluierungsmodul (EVM), mit dem sich ein äußerst leistungsfähiges, aber dennoch preiswertes Nahinfrarotspektrometer entwickeln lässt. Dieses flexible Tool enthält alles, um sofort mit der Entwicklung eines DLP-basierten Spektrometers zu beginnen. Das EVM (...)
ANHUA-3P-DLP4500NIR-I — AnHua Optoelectronics optische Module für industrielle Anwendungen mit DLP4500NIR
ANHUA-3P-DLP45OPTICALMOD — Optische Module von Anhua Opto DLP4500
EKB-3P-DLP4500EVM — EKB DLP4500-Evaluierungsmodule
KP-3P-DLP4500EVM — Keynote Photonics DLP4500-Evaluierungsmodule
The LC4500-RGB optical engine provides a full color, high resolution projector for your display applications. Excellent uniformity and short focus capability enable a wide range of applications. The (...)
KST-3P-DLP2010NIR — KS Technologies Quellcode für NIRScanNano Demo-App + SDK
DLPR350 — DLPC350 Konfigurations- und Support-Firmware
DMD-DIFFRACTION-EFFICIENCY-CALCULATOR — Calculator helps model DMD diffraction patterns and diffraction efficiency
Unterstützte Produkte und Hardware
Produkte
Mehrkanal-ICs (PMICs)
DMDs für Heimkino, Unternehmen & Bildungswesen
Tragbare DMDs & Verbraucher-DMDs
UV-DMDs (<420 nm)
Pro-AV- & Großraum-DMDs
Außenbeleuchtungs- & Projektions-DMDs
NIR-DMDs (>700 nm)
DMDs für Displays im Innenraum
DMDs für sichtbare Spektren (420 bis 700 nm)
DLP-Controller & -Treiber
Hardware-Entwicklung
Evaluierungsplatine
Entwicklungskit
Support-Software
DLPR069 — Series 310 DMD Mounting and Electrical Interconnect Information
Unterstützte Produkte und Hardware
Produkte
NIR-DMDs (>700 nm)
DMDs für sichtbare Spektren (420 bis 700 nm)
DLP-OMM-SEARCH — Suchtool für optische Module von DLP®-Produkten
DLP-OPTICAL-DESIGN — DLP-OPTICAL-DESIGN-GUIDELINES
Unterstützte Produkte und Hardware
Produkte
Mehrkanal-ICs (PMICs)
DMDs für Heimkino, Unternehmen & Bildungswesen
Tragbare DMDs & Verbraucher-DMDs
UV-DMDs (<420 nm)
Pro-AV- & Großraum-DMDs
Außenbeleuchtungs- & Projektions-DMDs
NIR-DMDs (>700 nm)
DMDs für Displays im Innenraum
DMDs für sichtbare Spektren (420 bis 700 nm)
DLP-Controller & -Treiber
Hardware-Entwicklung
Evaluierungsplatine
Entwicklungskit
Support-Software
TIDA-00155 — Referenzdesign für DLP-NIR-Spektrometer zur optischen Analyse von Flüssigkeiten und Festkörpern
| Gehäuse | Pins | CAD-Symbole, Footprints und 3D-Modelle |
|---|---|---|
| DLP-S310 (FQD) | 98 | Ultra Librarian |
Bestellen & Qualität
- RoHS
- REACH
- Bausteinkennzeichnung
- Blei-Finish/Ball-Material
- MSL-Rating / Spitzenrückfluss
- MTBF-/FIT-Schätzungen
- Materialinhalt
- Qualifikationszusammenfassung
- Kontinuierliches Zuverlässigkeitsmonitoring
- Werksstandort
- Montagestandort
Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.
Support und Schulungen
TI E2E™-Foren mit technischem Support von TI-Ingenieuren
Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.
Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support.