Produktdetails

Product type Analog output with integrated comparator Common-mode voltage (max) (V) 36 Common-mode voltage (min) (V) 0 Input offset (±) (max) (µV) 30, 50, 80 Input offset drift (±) (typ) (µV/°C) 0.02 Features Alert Function, Bidirectional, High precision, Low-side Capable Rating Catalog Voltage gain (V/V) 20, 50, 100 CMRR (min) (dB) 100 Bandwidth (kHz) 400, 440, 550 Iq (max) (mA) 1.15 Number of channels 1 Comparators (#) 2 Gain error (%) 0.075, 0.1, 0.15 Gain error drift (±) (max) (ppm/°C) 10 Slew rate (V/µs) 4 Operating temperature range (°C) -40 to 125
Product type Analog output with integrated comparator Common-mode voltage (max) (V) 36 Common-mode voltage (min) (V) 0 Input offset (±) (max) (µV) 30, 50, 80 Input offset drift (±) (typ) (µV/°C) 0.02 Features Alert Function, Bidirectional, High precision, Low-side Capable Rating Catalog Voltage gain (V/V) 20, 50, 100 CMRR (min) (dB) 100 Bandwidth (kHz) 400, 440, 550 Iq (max) (mA) 1.15 Number of channels 1 Comparators (#) 2 Gain error (%) 0.075, 0.1, 0.15 Gain error drift (±) (max) (ppm/°C) 10 Slew rate (V/µs) 4 Operating temperature range (°C) -40 to 125
TSSOP (PW) 14 32 mm² (5 mm × 6.4 mm)
  • Wide common-mode input range: –0.1 V to +36 V
  • Dual comparator outputs:
    • INA302: Two independent overlimit alerts
    • INA303: Window comparator
    • Threshold levels set individually
    • Comparator 1 alert response: 1 µs
    • Comparator 2 adjustable delay: 2 µs to 10 s
    • Open-drain outputs with independent latch control modes
  • High accuracy amplifier:
    • Offset voltage: 30 µV (max, A3 version)
    • Offset voltage drift: 0.5 µV/°C (max)
    • Gain error: 0.15% (max, A3 version)
    • Gain error drift: 10 ppm/°C
  • Available amplifier gains:
    • INA302A1, INA303A1: 20 V/V
    • INA302A2, INA303A2: 50 V/V
    • INA302A3, INA303A3: 100 V/V
  • Wide common-mode input range: –0.1 V to +36 V
  • Dual comparator outputs:
    • INA302: Two independent overlimit alerts
    • INA303: Window comparator
    • Threshold levels set individually
    • Comparator 1 alert response: 1 µs
    • Comparator 2 adjustable delay: 2 µs to 10 s
    • Open-drain outputs with independent latch control modes
  • High accuracy amplifier:
    • Offset voltage: 30 µV (max, A3 version)
    • Offset voltage drift: 0.5 µV/°C (max)
    • Gain error: 0.15% (max, A3 version)
    • Gain error drift: 10 ppm/°C
  • Available amplifier gains:
    • INA302A1, INA303A1: 20 V/V
    • INA302A2, INA303A2: 50 V/V
    • INA302A3, INA303A3: 100 V/V

The INA302 and INA303 (INA30x) devices feature a high common-mode, bidirectional, current-sensing amplifier and two high-speed comparators to detect out-of-range current conditions. The INA302 comparators are configured to detect and respond to overcurrent conditions. The INA303 comparators are configured to respond to both overcurrent and undercurrent conditions in a windowed configuration. These devices feature an adjustable limit threshold range for each comparator set using an external limit-setting resistor. These current-shunt monitors can measure differential voltage signals on common-mode voltages that can vary from –0.1 V up to +36 V, independent of the supply.

The open-drain alert outputs can be configured to operate in either a transparent mode (output status follows the input state), or in a latched mode (alert output is cleared when the latch is reset). The alert response time for comparator 1 is under 1 µs, and the alert response for comparator 2 is set through an external capacitor ranging from 2 µs to 10 s.

These devices operate from a single 2.7-V to 5.5-V supply, drawing a maximum supply current of 950 µA. The devices are specified over the extended operating temperature range of –40°C to +125°C, and are available in a 14-pin TSSOP package.

The INA302 and INA303 (INA30x) devices feature a high common-mode, bidirectional, current-sensing amplifier and two high-speed comparators to detect out-of-range current conditions. The INA302 comparators are configured to detect and respond to overcurrent conditions. The INA303 comparators are configured to respond to both overcurrent and undercurrent conditions in a windowed configuration. These devices feature an adjustable limit threshold range for each comparator set using an external limit-setting resistor. These current-shunt monitors can measure differential voltage signals on common-mode voltages that can vary from –0.1 V up to +36 V, independent of the supply.

The open-drain alert outputs can be configured to operate in either a transparent mode (output status follows the input state), or in a latched mode (alert output is cleared when the latch is reset). The alert response time for comparator 1 is under 1 µs, and the alert response for comparator 2 is set through an external capacitor ranging from 2 µs to 10 s.

These devices operate from a single 2.7-V to 5.5-V supply, drawing a maximum supply current of 950 µA. The devices are specified over the extended operating temperature range of –40°C to +125°C, and are available in a 14-pin TSSOP package.

Herunterladen Video mit Transkript ansehen Video

Ähnliche Produkte, die für Sie interessant sein könnten

Ähnliche Funktionalität wie der verglichene Baustein.
INA301 AKTIV Hochpräziser Strommessverstärker mit Komparator, 36 V, 550 kHz, 4 V/µs The INA301 has a single ALERT with similar performance
INA303 AKTIV Hochpräziser, bidirektionaler Strommessverstärker, 36 V, 550 kHz, 4 V/µs, mit Fensterkomparator The INA303 has window comparotor functionality

Technische Dokumentation

Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 16
Top-Dokumentation Typ Titel Format-Optionen Neueste englische Version herunterladen Datum
* Datenblatt INA30x 36-V, Overcurrent Protection, Precision, Current-Sense Amplifiers With Dual Integrated Comparators datasheet (Rev. C) PDF | HTML 26.03.2019
Anwendungshinweis Using a PCB Copper Trace as a Current Sense Shunt Resistor (Rev. A) PDF | HTML 27.04.2026
Anwendungshinweis Risks and Prevention of ESD, EOS, and Latch Up Events for Current Sense Amplifiers PDF | HTML 18.11.2024
Application brief Integrating the Current Sensing Resistor (Rev. D) PDF | HTML 07.04.2023
E-book An Engineer's Guide to Current Sensing (Rev. B) 12.04.2022
Application brief Measuring Current To Detect Out-of-Range Conditions (Rev. D) PDF | HTML 10.03.2022
Application brief Measuring Current for Handle Multiple Out-of-Range Conditions (Rev. C) PDF | HTML 04.10.2021
Application brief Integrating the Current Sensing Signal Path (Rev. B) PDF | HTML 29.09.2021
Auswahlhilfe Current Sense Amplifiers (Rev. E) 20.09.2021
Application brief High-Side Motor Current Monitoring for Over-Current Protection (Rev. B) PDF | HTML 23.02.2021
Application brief Bidirectional, Low-Side Phase Current Sensing With Onboard Overcurrent Detection (Rev. D) 06.03.2019
Application brief External current sense amps vs integrated onboard amplifiers for current sensing (Rev. B) 19.02.2019
Circuit design Overcurrent event detection circuit 31.07.2018
Anwendungshinweis Closed-Loop Analysis of Load-Induced Amplifier Stability Issues Using Zout 27.10.2017
Application brief Low-Drift, Low-Side Current Measurements for Three-Phase Systems (Rev. B) 05.09.2017
Whitepaper Overcurrent protection enables more efficient and reliable systems 16.05.2016

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

INA302EVM — INA302 Highspeed-Präzisions-Stromsensor-Verstärker – Evaluierungsmodul

Das Evaluierungsmodul (EVM) INA302EVM ist eine kompakte, benutzerfreundliche Plattform zur Evaluierung der Hauptmerkmale und Leistung des präzisen Highspeed-Strommessverstärkers INA302 mit zwei integrierten Komparatoren in seinen spezifizierten Eingangsstrom-, Gleichtaktspannungs- und (...)
Benutzerhandbuch: PDF
Unterstützte Produkte und Hardware
Vorrätig
Limit:
??asset.out-of-stock-ti_de_DE??
Nicht verfügbar
Simulationsmodell

INA302 PSpice Model

SBOMB41.ZIP (64 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA302 TINA-TI Reference Design

SBOMAC2.TSC (324 KB) - TINA-TI-Referenzdesign
Unterstützte Produkte und Hardware
Simulationsmodell

INA302 TINA-TI Spice Model

SBOMAC1.ZIP (30 KB) - TINA-TI Spice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA302A1 PSpice Model

SBOMBH3.ZIP (35 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA302A2 PSpice Model

SBOMBH4.ZIP (35 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA302A3 PSpice Model

SBOMBH5.ZIP (35 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Berechnungstool

ANALOG-ENGINEER-CALC — PC software analog engineer's calculator

Der Rechner für Analogtechniker beschleunigt viele der sich wiederholenden Berechnungen, die Entwickler von analogen Schaltungsdesigns regelmäßig durchführen müssen. Dieses PC-basierte Tool bietet eine grafische Schnittstelle mit einer Liste verschiedener gebräuchlicher Berechnungen. Das Spektrum (...)

Unterstützte Produkte und Hardware
Berechnungstool

CS-AMPLIFIER-ERROR-TOOL — Current Sense Amplifier Comparison and Error Tool

Dieser Excel-Rechner bietet einen Vergleich zwischen zwei und fünf unserer Standard-Strommessverstärker und stellt eine Tabelle mit den grundlegenden Parametern der einzelnen Bausteine bereit. Dieser Rechner nimmt außerdem die vom Benutzer gemachten Systemzustandseingaben wie Gleichtaktspannung, (...)
Unterstützte Produkte und Hardware
Designtool

CIRCUIT060034 — Überstromereigniserfassungsschaltung

Hierbei handelt es sich um eine unidirektionale Strommesslösung, welche allgemein als Überstromschutz (OCP) bezeichnet wird. Sie kann ein Überstromwarnsignal bereitstellen, um ein System abzuschalten, wenn ein bestimmter Schwellenstrom erreicht wird, und das System wieder aktivieren, sobald der (...)
Unterstützte Produkte und Hardware
Referenzdesign

TIDA-00302 — Strom-Shunt-Monitor mit transienter Robustheit – Referenzdesign

This high-side current shunt monitor is used to measure the voltage developed across a current-sensing resistor when current passes through it.

Additionally, an external protection circuit is implemented to provide surge and fast-transient protection and demonstrate the different immunity levels to (...)

Unterstützte Produkte und Hardware
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
TSSOP (PW) 14 Ultra Librarian

Bestellen & Qualität

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videoreihe

Alle Videos anzeigen

Videos