The BQ40Z80 offers lifetime
data logging for several critical battery parameters. The following parameters are
updated every 10 hours if a difference is detected between values in RAM and data
flash:
- Maximum and minimum cell voltages
- Maximum delta cell voltage
- Maximum charge current
- Maximum discharge current
- Maximum average discharge current
- Maximum average discharge power
- Maximum and minimum cell temperature
- Maximum delta cell temperature
- Maximum and minimum internal sensor temperature
- Maximum FET temperature
- Number of safety events occurrences and the last cycle of the occurrence
- Number of valid charge termination and the last cycle of the valid charge
termination
- Number of Qmax and Ra updates and the last cycle of the Qmax and Ra updates
- Number of shutdown events
- Cell balancing time for each
cell, this data is updated every two hours if a difference is detected
- Total FW runtime and time spent
in each temperature range, this data is updated every two hours if a difference
is detected