SNVSBJ0B December 2019 – August 2021 LM5170
PRODUCTION DATA
To operate the converter at the desired switching frequency FSW, select the ROSC by satisfying Equation 17, namely,
Choose the closest standard resistor, that is, ROSC = 40.2 kΩ.