SBOSAL6A June 2025 – September 2025 XTR200
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
The XTR200 has internal circuitry that detects the error states listed in Table 6-1. When an error state is detected, the error flag EF (an open-drain logic output), pulls low. This digital output can be pulled up to an external logic voltage through a resistor. The internal pullup current is 4μA to an internal 3.3V reference.
| Error State | Description |
|---|---|
| Output short | Short-circuit current limit reached in voltage-output mode |
| Output open | Unable to reach correct output current in current-output mode. This fault condition is only detectable with an input voltage of >350mV and a supply voltage of >10V. |
| Output saturation | Insufficient headroom between load voltage and supply voltage to achieve correct voltage or current output. This fault condition is only detectable with a supply voltage of >10V. |
| SET pin short | SET pin current exceeding 1/10th of the output short circuit current limit |
| Power supply under voltage | Power supply voltage under 8V |
| High die temperature | Die temperature exceeding 150°C |