SBOSAL6A June 2025 – September 2025 XTR200
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
The design requirements for this application are listed in Table 7-1. These are chosen to closely represent the design requirements of industrial field transmitters.
Although the standard ranges for transmitting information are 0mA to 20mA, 4mA to 20mA, and 0V to 10V, currents above 20mA and voltages above 10V are often used to indicate error conditions. This is why the design requirements specify output currents up to 22mA and output voltages up to 11.25V.
| Parameter | Value |
|---|---|
| Input voltage range | 0V to 3V |
| Power supply voltage | 18V to 36V |
| Output current range | 0mA to 22mA |
| Output voltage range | 0V to 11.25V |
| Operating temperature range | –40°C to 85°C |
| Load Resistance (Current Output) | 0Ω to 500Ω |
| Load Resistance (Voltage Output) | >1000Ω |