SBASAI9 December 2025 ADS112S14 , ADS122S14
PRODUCTION DATA
Commands are used to read and write register data. The register map consists of a series of one-byte (8 bit) registers, accessible by read and write operations. The minimum frame length of the input command sequence is 16 bit (24 bit when SPI CRC is enabled). If desired, the input command sequence can be padded with leading zeros to match the length of the output data frame. When the SPI CRC is enabled, the device interprets the two bytes preceding the CRC-IN byte at the end of the frame as the command bytes. Table 7-11 shows the ADS1x2S14 commands.
| DESCRIPTION | BYTE 1 | BYTE 2 | BYTE 3 (Optional CRC-IN Byte) |
|---|---|---|---|
| No operation (read conversion data) | 00h | 00h | D7h |
| Read register command | 40h + address [3:0] | Don't care | CRC-IN of byte 1 and byte 2 |
| Write register command | 80h + address [3:0] | Register data | CRC -IN of byte 1 and byte 2 |
The device supports special extended-length bit patterns that are longer than the standard command length. These patterns are used to reset the ADC and to reset the frame in 3-wire SPI mode. The extended bit patterns are explained in the Reset by SPI Input Pattern and 3-Wire SPI Mode sections.
The instance where the commands are latched by the device depend on the SPI mode: