SBASAX4 June 2026 ADS9316 , ADS9317
PRODUCTION DATA
The ADS931x operates either as a single converter or in a system with multiple converters. To take advantage of the simple, high-speed, SPI serial interface, cascade converters in a daisy-chain configuration when multiple converters are used. No register configuration is required to enable daisy-chain mode. Figure 6-24 shows a typical connection of three converters in daisy-chain mode.
When the ADS931x is connected in daisy-chain mode, make sure the device operates in 1-lane interface mode by writing 110b to NUM_DATA_LANES. See the Data Interface section. The serial input data passes through the device with a 48 SCLK delay as long as CS is active. Figure 6-25 illustrates a detailed timing diagram of this mode when the conversion in each converter is performed simultaneously.