SBASAX4 June 2026 ADS9316 , ADS9317
PRODUCTION DATA
To enable moving data averaging, select the averaging window size by writing to MAVG_MODE in address 0x0D. in register bank 1. The moving average window size is user-selectable between 2, 4, and 8 conversions.
Table 6-7 specifies the improvement in SNR with moving data averaging. Figure 6-16 illustrates the ADC output timing for a moving average of four samples.
| OVERSAMPLING RATIO | SNR - ADS9317 (18-BIT) | MAXIMUM OUTPUT DATA RATE |
|---|---|---|
| No averaging | 95.4dB | 5MSPS |
| 2 | 98.5dB | 5MSPS |
| 4 | 100.8dB | 5MSPS |
| 8 | 102.9dB | 5MSPS |