SBASAX4 June 2026 ADS9316 , ADS9317
PRODUCTION DATA
The ADS931x implements a register map lock feature that prevents an accidental or unintended write to the device registers. By default, the device register map is locked. Unlock the register map by following the sequence shown in Table 6-17 before writing or reading a register.
| STEP NUMBER | REGISTER | ||
|---|---|---|---|
| BANK | ADDRESS | VALUE[15:0] | |
| 1 | 0 | 0xFE | 0xB38F |
| 2 | 0 | 0xFE | 0xABCD |
After writing or reading registers, lock the register map to prevent unintended register writes. Writing any value other than the register map unlock sequence to address 0xFE locks the register map. Table 6-15 shows an example sequence to lock the device register map.
| STEP NUMBER | REGISTER | ||
|---|---|---|---|
| BANK | ADDRESS | VALUE[15:0] | |
| 1 | 0 | 0xFE | 0x1234 |