The data that was captured per run is
listed below. Only Events that were considered transients were captured.
- Elapsed Time (s): Total Time
of Run
- Initial Local (C): Local
Temperature of DUT without radiation exposure before run
- Initial Remote (C): Remote
Temperature of DUT without radiation exposure before run
- Temp Delta Threshold (C): Set
temperature error threshold to be considered an event for both local and remote
channels
- Current Local (C): Current
local temperature during exposure
- Current Remote (C): Current
remote temperature during exposure
- Number of Delta Events: Number
of events counted
- Number of Reset Events: Number
of resets with general-call address
- TMP119 Temp: TMP119 was placed
on the backside of the board for reference
- Therm Pins: Alert and THERM
Pin signal captured during the exposure. Data came in as binary values indicating if
the alert or THERM signal was turned on
- Register Map: Local Hi Byte
(0x00), Remote Hi Byte (0x01), Status (0x02), Configuration (0x03), Conversion Rate
(0x04), Local Hi Limit (0x05), Local Low Limit (0x06), Rem Hi Limit (0x07) , Rem Low
Limit (0x08), Remote Low Byte (0x10), Rem Offset Hi Byte (0x11), Rem Offset Low Byte
(0x12), Rem Hi Limit (0x13), Rem Low Limit (0x14), Local Low Byte (0x15), Channel
Enable (0x16), Remote THERM Limit (0x19), Local THERM Limit (0x20), THERM Hysteresis
(0x21), Consecutive ALERT (0x22), n-factor correction (0x23), Digital Filter (0x24),
Manuf. ID (0xFE).