SBOK097B April   2025  – June 2025 TMP9R01-SEP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. Introduction
  5. Sample Identification
  6. Irradiation Facility and Setup
  7. Die Micro-section
  8. Test Set-Up
  9. SEL Results
    1. 6.1 TMP9R01-SEP SEL Data
  10. SET Results
    1. 7.1 Summary of SET Results
      1. 7.1.1 Local Temperature Reads
        1. 7.1.1.1 Analog Alert Captures
    2. 7.2 Cross Section Events and Event Rate Calculations
  11. Detailed Results Per Run
    1. 8.1 Detailed Run Raw Data
  12. Summary
  13. 10Glossary
  14. 11Revision History

Analog Alert Captures

Scope shots of the alert signal were captured during the exposure. There were 4 common transient captures. The following captures shown below was captured with no resets to highlight to worse case with the alert signal.

1) The alert signal can directly switch from off to on.

 Possible Alert Signal Trip During
                Exposure Figure 7-7 Possible Alert Signal Trip During Exposure

2) The alert signal can gradually ramp down with a 0.03ms changing period.

 Possible Alert Signal Trip During
                Exposure Figure 7-8 Possible Alert Signal Trip During Exposure

3) This plot highlights the recovery of an event.

 Possible Alert Signal Trip During
                Exposure Figure 7-9 Possible Alert Signal Trip During Exposure

4) This plot highlights the largest voltage drop captured during exposure.

 Possible Alert Signal Trip During
                Exposure Figure 7-10 Possible Alert Signal Trip During Exposure