SBOK097B April 2025 – June 2025 TMP9R01-SEP
Scope shots of the alert signal were captured during the exposure. There were 4 common transient captures. The following captures shown below was captured with no resets to highlight to worse case with the alert signal.
1) The alert signal can directly switch from off to on.
2) The alert signal can gradually ramp down with a 0.03ms changing period.
3) This plot highlights the recovery of an event.
4) This plot highlights the largest voltage drop captured during exposure.