SBOK097B April   2025  – June 2025 TMP9R01-SEP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. Introduction
  5. Sample Identification
  6. Irradiation Facility and Setup
  7. Die Micro-section
  8. Test Set-Up
  9. SEL Results
    1. 6.1 TMP9R01-SEP SEL Data
  10. SET Results
    1. 7.1 Summary of SET Results
      1. 7.1.1 Local Temperature Reads
        1. 7.1.1.1 Analog Alert Captures
    2. 7.2 Cross Section Events and Event Rate Calculations
  11. Detailed Results Per Run
    1. 8.1 Detailed Run Raw Data
  12. Summary
  13. 10Glossary
  14. 11Revision History

Summary

This report summarizes all SEE data collected on the TMP9R01-SEP. This document provides the understanding of how the device performs under radiation. The data shows the TMP9R01-SEP is SEL free up to 50.5MeV. A SET study was done by monitoring the temperature readout of the remote and local channels and recording events greater than ±1.5°C from the initial recorded temperatures.