SBOS258E November 2002 – April 2025 OPA698
PRODUCTION DATA
Figure 8-25 shows a dc restore circuit using the OPA698 and OPA660. The buffer element of the OPA660 is used to buffer the input signal while the transconductance element is used to restore the dc level after the decoupling capacitor C1. The dc level is set using R1 and R2. The OPA698 is configured at a gain of 2V/V to compensate for the 75Ω series into a 75Ω load. The OPA698 also limits the output to ground.
Figure 8-25 DC Restore to Ground