SDAA170 September   2026 TPS61383-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
  5. 2Design Requirement and System Structure
    1. 2.1 Design Requirements
    2. 2.2 System Structure
      1. 2.2.1 Centralized E‑Latch System
      2. 2.2.2 Distributed E‑Latch System
  6. 3Power Train
    1. 3.1 Integrated E-Latch Power Train with TPS61383-Q1
      1. 3.1.1 Super Capacitor Charger Function Introduction
      2. 3.1.2 Boost Function Introduction
      3. 3.1.3 Super Capacitor Bleeding
    2. 3.2 Hardware Design Procedure
      1. 3.2.1 Selecting the External MOSFET
      2. 3.2.2 Inductor Selection
      3. 3.2.3 Capacitor in Super Capacitor Side
      4. 3.2.4 Boost Output Capacitor
      5. 3.2.5 Loop Compensation Design
      6. 3.2.6 Key Considerations
    3. 3.3 Software Initial Process
  7. 4Super Capacitor Energy Modeling Basis and Selection
    1. 4.1 Discharge Profile and Cut-off Voltage
    2. 4.2 Super Capacitor Discharge Energy Modeling
    3. 4.3 Calculation Example
    4. 4.4 Super Capacitor Excel Calculation Tool
  8. 5Super Capacitor Management
    1. 5.1 Voltage Monitoring with BQ76907-Q1
    2. 5.2 Cell Balancing with BQ76907-Q1
      1. 5.2.1 Balancing Strategy
      2. 5.2.2 I2C Implementation
      3. 5.2.3 Cell Balancing Current
      4. 5.2.4 Low-Side Protection Circuit Design Considerations
    3. 5.3 Super Capacitor Health Detection: Combined Solution of TPS61383-Q1 and BQ76907-Q1
  9. 6Control Unit and Communication
    1. 6.1 Control Unit Design Consideration
    2. 6.2 SBC Selection
  10. 7Execution Unit
    1. 7.1 Motor Driver Structure
    2. 7.2 Motor Driver Design Considerations
  11. 8Summary
  12. 9References

Centralized E‑Latch System

In a centralized architecture, a single crash‑unlock actuator is installed at the central body control module (BCM) or a dedicated door zone module. From there, mechanical rods or cables distribute the crash‑unlock force to all four doors simultaneously.

Energy Requirement:

  1. 6-10 locks for 4 doors, around 200J for unlocking all locks
  2. 3-4 cells super capacitor

Advantages:

  1. Only one high‑reliability crash actuator needed, lower system cost.
  2. Easier functional safety validation for the crash path.

Disadvantages

  1. Mechanical linkage from central actuator to each door still have the risk of damage.
  2. If the central actuator fails, all doors lose crash‑unlock capability.
  3. Slower crash response due to mechanical transmission delay.
There are two different type of structure for centralized e‑Latch system.
  • CPM (Crash Power Module) – The backup power system responsible for unlatching operations. CPM provides only the backup power supply and does not integrate execution unit in e-latch module. When a car accident occurs, the CPM powers the door module and the unlock is executed by door module.
 CPM Structure Figure 2-1 CPM Structure
  • CUPM (Crash Unlock Power Module) – A secondary module that provides a backup unlocking capability when the primary system fails. The ‘U’ signifies ‘Unlock’. CUPM not only provides backup power supply but also integrates secondary execution unit. When a car accident occurs, the CUPM is able to unlock by itself even if motor driver in door module is damaged. There are two different types of structure for CUPM:

For cars which integrates latch motor driver inside the car body, CUPM usually uses the centralized motor driver as excution unit:

 CUPM Structure with
                    Centralized Motor Driver Figure 2-2 CUPM Structure with Centralized Motor Driver

Other cars place the motor driver locally in the door module. In this case the CUPM needs additional high side switch as backup execution unit:

 CUPM Structure with
                    Centralized Motor Driver Figure 2-3 CUPM Structure with Centralized Motor Driver