In a centralized architecture, a
single crash‑unlock actuator is installed at the central body control module (BCM)
or a dedicated door zone module. From there, mechanical rods or cables distribute
the crash‑unlock force to all four doors simultaneously.
Energy Requirement:
- 6-10 locks for 4 doors, around
200J for unlocking all locks
- 3-4 cells super capacitor
Advantages:
- Only one high‑reliability crash
actuator needed, lower system cost.
- Easier functional safety
validation for the crash path.
Disadvantages
- Mechanical linkage from central
actuator to each door still have the risk of damage.
- If the central actuator fails,
all doors lose crash‑unlock capability.
- Slower crash response due to
mechanical transmission delay.
There are two different type of structure for centralized e‑Latch system.
- CPM (Crash Power Module) – The
backup power system responsible for unlatching operations. CPM provides only the
backup power supply and does not integrate execution unit in e-latch module.
When a car accident occurs, the CPM powers the door module and the unlock is
executed by door module.
- CUPM (Crash Unlock Power Module)
– A secondary module that provides a backup unlocking capability when the
primary system fails. The ‘U’ signifies ‘Unlock’. CUPM not only provides backup
power supply but also integrates secondary execution unit. When a car accident
occurs, the CUPM is able to unlock by itself even if motor driver in door module
is damaged. There are two different types of structure for CUPM:
For cars which integrates latch
motor driver inside the car body, CUPM usually uses the centralized motor driver as
excution unit:
Other cars place the motor
driver locally in the door module. In this case the CUPM needs additional high side
switch as backup execution unit: