SDAA170 September 2026 TPS61383-Q1
The BQ76907-Q1 battery monitor integrates a multiplexed voltage ADC that measures individual cell voltages differentially, processes the results with on-chip calibration, and exposes each result as a signed 16-bit integer via I²C direct commands. The ADC runs a continuous ADSCAN loop in NORMAL mode. Each loop slot width is independently programmable (366μs, 732μs, 1.46ms, 2.93ms), trading conversion speed for effective resolution (13–16 bits). The default cell slot width of 2.93 ms delivers 16-bit effective resolution. In SLEEP mode the ADC runs a full burst on a programmable timer interval and then idles to save power. Taking normal mode as an example, this section describes the basic steps to implement a reliable cell voltage readout in firmware.
| Slot | Measurement |
|---|---|
| 0 | Cell 1 Voltage (VC1 − VC0) |
| 1 | Cell 2 Voltage (VC2 − VC1) |
| 2 | Cell 3 Voltage (VC3 − VC2) |
| 3 | Cell 4 Voltage (VC4 − VC3) |
| 4 | Cell 5 Voltage (VC5 − VC4) |
| 5 | Cell 6 Voltage (VC6 − VC5) |
| 6 | Cell 7 Voltage (VC7 − VC6) |
| 7 | Shared Slot (rotates: TS, Int Temp, Stack, REG18, VSS) |
All cell voltages are exposed as direct I²C commands. Each command occupies two consecutive register addresses containing the little-endian signed 16-bit result in millivolts. The low byte is at the even (base) address; the high byte is at the odd (base+1) address.
| Address | Name | Type | Unit | Access |
|---|---|---|---|---|
| 0x14–0x15 | Cell 1 Voltage | I2 | mV | R |
| 0x16–0x17 | Cell 2 Voltage | I2 | mV | R |
| 0x18–0x19 | Cell 3 Voltage | I2 | mV | R |
| 0x1A–0x1B | Cell 4 Voltage | I2 | mV | R |
| 0x1C–0x1D | Cell 5 Voltage | I2 | mV | R |
| 0x1E–0x1F | Cell 6 Voltage | I2 | mV | R |
| 0x20–0x21 | Cell 7 Voltage | I2 | mV | R |
| 0x26–0x27 | Stack Voltage | U2 | mV | R |
BQ76907-Q1 returns 16 bits ADC data in little-endian order. Taking Cell 1 voltage as an example. Register 0x14 holds bits [7:0] (LSB); register 0x15 holds bits [15:8] (MSB). The value is in millivolts, so no scaling is required. Negative values (possible if a cell input is driven slightly below its reference, within the −0.2 V minimum) are encoded in two’s complement.
| Register | Byte Role | Bit Range | Example (2700 mV) | Hex Value |
|---|---|---|---|---|
| 0x14 | LSB (Byte 0) | bits [7:0] | 2700 = 0x0A8C | 0x8C |
| 0x15 | MSB (Byte 1) | bits [15:8] | 2700 = 0x0A8C | 0x0A |
Therefore the reconstruction formula: voltage_mV = int16_t((Byte 1 << 8) | Byte 0)
The auto-increment behavior of the I²C block-read means that issuing a 2-byte read starting at address 0x14 returns Byte 0 first, then Byte 1 automatically, with no need to re-address. Cast the concatenated result to int16_t before use to correctly handle the two’s-complement sign. Therefore the byte format of reading the Cell 1 is: