SLAZ709A October   2017  – June 2025 MSP432E401Y , MSP432E411Y

 

  1.   1
  2. 1MSP432E4 SimpleLink™ Microcontrollers
    1. 1.1 Introduction
    2. 1.2 Device Nomenclature
    3. 1.3 Device Markings
    4. 1.4 Errata Overview
    5. 1.5 Errata Descriptions
      1.      ADC#13
      2.      ADC#14
      3.      EPI#01
      4.      GPIO#09
      5.      GPTM#09
      6.      GPTM#15
      7.      HIB#10
      8.      HIB#16
      9.      HIB#18
      10.      HIB#19
      11.      MEM#07
      12.      MEM#15
      13.      MEM#16
      14.      PWM#04
      15.      PWM#05
      16.      PWM#06
      17.      QEI#01
      18.      SSI#03
      19.      SSI#05
      20.      SSI#06
      21.      SSI#07
      22.      SSI#08
      23.      SYSCTL#03
      24.      SYSCTL#18
      25.      SYSCTL#24
      26.      USB#04
      27.      WDT#08
    6. 1.6 Appendix 1
    7. 1.7 Appendix 2
  3. 2Trademarks
  4. 3Revision History

QEI#01

When using the index pulse to reset the counter, a specific initial condition in the QEI module causes the direction for the first count to be misread

Description

When using the index pulse to reset the counter with the following configuration in the QEI Control (QEICTL) register:

  • SIGMODE is 0 indicating quadrature mode
  • CAPMODE is 1 indicating both PhA and PhB edges are counted

and the following initial conditions:

  • Both PhA and PhB are 0
  • The next quadrature state is in the counterclockwise direction

the QEI interprets the state change as an update in the clockwise direction, which results in a position mismatch of 2.

Workaround

None.