SLLSF09F
December 2017 – August 2026
ISO1042
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Transient Immunity
5.4
Recommended Operating Conditions
5.5
Thermal Information
5.6
Power Ratings
5.7
Insulation Specifications
5.8
Safety-Related Certifications
5.9
Safety Limiting Values
5.10
Electrical Characteristics - DC Specification
5.11
Switching Characteristics
5.12
Insulation Characteristics Curves
5.13
Typical Characteristics
6
Parameter Measurement Information
6.1
Test Circuits
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
CAN Bus States
7.3.2
Digital Inputs and Outputs: TXD (Input) and RXD (Output)
7.3.3
Protection Features
7.3.3.1
TXD Dominant Timeout (DTO)
7.3.3.2
Thermal Shutdown (TSD)
7.3.3.3
Undervoltage Lockout and Default State
7.3.3.4
Floating Pins
7.3.3.5
Unpowered Device
7.3.3.6
CAN Bus Short Circuit Current Limiting
7.4
Device Functional Modes
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedure
8.2.2.1
Bus Loading, Length and Number of Nodes
8.2.2.2
CAN Termination
8.2.3
Application Curve
8.2.3.1
Insulation Lifetime
8.3
DeviceNet Application
8.4
Power Supply Recommendations
8.5
Layout
8.5.1
Layout Guidelines
8.5.1.1
PCB Material
8.5.2
Layout Example
9
Device and Documentation Support
9.1
Documentation Support
9.1.1
Related Documentation
9.2
Receiving Notification of Documentation Updates
9.3
Support Resources
9.4
Trademarks
9.5
Electrostatic Discharge Caution
9.6
Glossary
10
Revision History
11
Mechanical, Packaging, and Orderable Information
1
Features
Meets the ISO 11898-2:2016 physical layer standard
Supports classic CAN up to 1Mbps and FD (Flexible Data Rate) up to 5Mbps
Low loop delay: 152ns
Protection features
DC bus fault protection voltage: ±70V
HBM ESD tolerance on bus pins: ±16kV
Driver Dominant Time Out (TXD DTO)
Undervoltage protection on V
CC1
and V
CC2
Common-Mode Voltage Range: ±30V
Ideal passive, high-impedance bus terminals when unpowered
High CMTI: 100kV/µs
V
CC1
voltage range: 1.71V to 5.5V
Supports 1.8V, 2.5V, 3.3V and 5.0V logic interface to the CAN controller
V
CC2
Voltage Range: 4.5V to 5.5V
Robust Electromagnetic Compatibility (EMC)
System-level ESD, EFT, and surge immunity
Low emissions
Ambient Temperature Range: –40°C to +125°C
16-SOIC and 8-SOIC package options
Automotive version available:
ISO1042-Q1
Safety-related certifications:
7071V
PK
V
IOTM
and 1500V
PK
V
IORM
(Reinforced and Basic Options) per
DIN EN IEC 60747-17 (VDE 0884-17)
5000V
RMS
Isolation for 1 Minute per UL 1577
GB 4943.1, IEC 62368-1, IEC 60601-1 and IEC 61010-1 certifications
CQC, TUV and CSA certifications