In the below images, VCCI and VCCO refers to the power supplies VDD and VISO, respectively.
A. CL = 15pF and The input pulse is
supplied by a generator having the following characteristics: PRR ≤ 50kHz, 50%
duty cycle, tr ≤ 3ns, tf ≤ 3ns, ZO = 50Ω. At
the input, 50Ω resistor is required to terminate Input Generator signal. The 50Ω
resistor is not needed in actual application.
B. B. CL = 15pF and includes instrumentation and fixture capacitance within ±20%.
Figure 6-1 Switching Characteristics Test Circuit and Voltage Waveforms
Note: A. CL = 15pF and includes instrumentation and fixture capacitance within ±20%.
Note: B. Power Supply Ramp Rate = 10mV/ns.
Figure 6-2 Default Output Delay Time Test Circuit and Voltage Waveforms
Note: CL = 15pF and includes instrumentation and fixture capacitance within ±20%.
Note: Pass-fail criteria: Outputs must remain stable.
Figure 6-3 Common-Mode Transient Immunity Test Circuit