SLOS187A February 1997 – July 2025 TLV2322 , TLV2324
PRODUCTION DATA
To obtain low-level supply-voltage operation, some compromise is necessary in the input stage. This compromise results in the device low-level output voltage being dependent on both the common-mode input voltage level as well as the differential input voltage level. When attempting to correlate low-level output readings with those quoted in the electrical specifications, observe these two conditions. If conditions other than these are to be used, see the Typical Characteristics in Section 5.10.