SLUSF91 December 2025 UCC23710
PRODUCTION DATA
Table 6-1 lists the device function.
| INPUT | OUTPUT | NOTE | ||||
|---|---|---|---|---|---|---|
| VCC | VDD | IF | DESAT | FLT | OUT | |
| PU | PD | X | NO | HiZ | LO | VDD UVLO |
| PU | PU | X | NO | HiZ | LO | DISABLED |
| PU | Open | X | NO | HiZ | HiZ | OPEN VDD |
| PU | PU | LO | NO | HiZ | LO | INPUT CONTROLLED |
| PU | PU | HI | NO | HiZ | HI | |
| PU | PU | LO | YES | LO | STO | DESAT/OC EVENT |
| PU | PU | HI | YES | LO | STO | |
| PD | PU | HI | YES | HiZ | STO | |
PU = Power Up (Supply greater than UVLO rising threshold); PD = Power Down (Supply less than UVLO falling threshold); X: Irrelevant; HI = Output High; LO = Output Low; HiZ = High Impedance, STO = Soft Turn-Off