A high-accuracy current sense amplifier (CSA) is used to monitor the input current during forward charging, or output current during OTG (IADPT) and the charge/discharge current (IBAT). IADPT voltage is 20× (IADPT_GAIN=0b) or 40× (IADPT_GAIN=1b) the differential voltage across ACP_A and ACN_A plus ACP_B and ACN_B. IBAT voltage is 8× (IBAT_GAIN=0b) or 64×(IBAT_GAIN=1b) of the differential across SRP and SRN. To lower the voltage on current monitoring, a resistor divider from the IADPT/IBAT output to GND can be used, and accuracy over temperature can still be achieved. TI recommends that the total resistance of the divider circuit be at least 100kΩ to prevent crashing the IADPT/IBAT pin voltage.
A maximum 100pF capacitor is recommended to connect on the output for decoupling high-frequency noise. An additional RC filter is optional. Note that the RC filtering has additional response delay. The IADPT and IBAT output voltages are clamped at 3.2V.