SLVSDM4F November 2018 – October 2026 TPS1HA08-Q1
PRODUCTION DATA
Some applications operate with a high-frequency, low duty-cycle PWM. Such applications require fast settling of the SNS output. For example, a 250Hz, 5% duty-cycle PWM has an on-time of only 200µs. The microcontroller ADC can sample the SNS signal after the defined settling time, tSNSION3.
Figure 8-13 Current Sensing in Low-Duty Cycle Applications