SLVSJC6 December 2025 TPS544B27W
PRODUCTION DATA
STATUS_VOUT is shown in Figure 7-49 and described in Table 7-69.
Return to the Summary Table.
Write Transaction: Write Byte
Read Transaction: Read Byte
Data Format: unsigned binary (1 byte)
NVM Back-up: No
Updates: On-the-fly The STATUS_VOUT command returns one byte of information relating to the status of the converter's output voltage related faults and warnings as follows. The status bits remain latched even after the fault or warning condition is resolved. The bits can be cleared by:
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| OVF | OVW | UVW | UVF | VO_MAX_MIN_W | RESERVED | RESERVED | RESERVED |
| R/W1C-0h | R/W1C-0h | R/W1C-0h | R/W1C-0h | R/W1C-0h | R-0h | R-0h | R-0h |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | OVF | R/W1C | 0h | This latched bit is set if the output voltage exceeds either the relative threshold configured with the VOUT_OV_FAULT_LIMIT command or the absolute threshold selected with the SEL_FIX_OVF bit field in the SYS_CFG_USER1 command.
|
| 6 | OVW | R/W1C | 0h | This latched bit is set if the output voltage exceeds the relative threshold as configured with the VOUT_OV_WARN_LIMIT command.
|
| 5 | UVW | R/W1C | 0h | This latched bit is set if the output voltage goes below the relative threshold as configured with the VOUT_UV_WARN_LIMIT command. This bit will also be set in the event of a UVF.
|
| 4 | UVF | R/W1C | 0h | This latched bit is set if the output voltage goes below the relative threshold as configured with the VOUT_UV_FAULT_LIMIT command.
|
| 3 | VO_MAX_MIN_W | R/W1C | 0h | This latched bit is set if an attempt to set the output voltage through the PMBus interface is limited by the VOUT_MAX command. Refer to the VOUT_MAX command description for more details.
|
| 2 | RESERVED | R | 0h | |
| 1 | RESERVED | R | 0h | |
| 0 | RESERVED | R | 0h |