SLVSJC6 December 2025 TPS544B27W
PRODUCTION DATA
STATUS_TEMPERATURE is shown in Figure 7-52 and described in Table 7-72.
Return to the Summary Table.
Write Transaction: Write Byte
Read Transaction: Read Byte
Data Format: unsigned binary (1 byte)
NVM Back-up: No
Updates: On-the-fly The STATUS_TEMPERATURE command returns one byte of information relating to the status of the converter's temperature related faults and warnings as follows. The status bits remain latched even after the fault or warning condition is resolved. The bits can be cleared by:
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| OTF_PROG | OTW_PROG | RESERVED | RESERVED | RESERVED | RESERVED | RESERVED | RESERVED |
| R/W1C-0h | R/W1C-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | OTF_PROG | R/W1C | 0h | This latched bit is set if the READ_TEMPERATURE_1 telemetry exceeds the threshold as configured with the OT_FAULT_LIMIT command.
|
| 6 | OTW_PROG | R/W1C | 0h | This latched bit is set if the READ_TEMPERATURE_1 telemetry exceeds the threshold as configured with the OT_WARN_LIMIT command.
|
| 5 | RESERVED | R | 0h | |
| 4 | RESERVED | R | 0h | |
| 3 | RESERVED | R | 0h | |
| 2 | RESERVED | R | 0h | |
| 1 | RESERVED | R | 0h | |
| 0 | RESERVED | R | 0h |