OT_WARN_LIMIT is shown in Figure 7-40 and described in Table 7-57.
Return to the Summary Table.
Write Transaction: Write Word
Read Transaction: Read Word
Data Format: LINEAR11
NVM Back-up: EEPROM
Updates: On-the-fly The OT_WARN_LIMIT command sets the temperature, in degrees Celsius, of the device that causes an overtemperature warning condition. This is implemented in the internal telemetry system by performing a digital comparison of the output of the READ_TEMPERATURE_1 telemetry to the warning threshold. Upon triggering the warning the device:
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| EXPONENT[4:0] | RESERVED | RESERVED | RESERVED | ||||
| R-2h | R-0h | R-0h | R-0h | ||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | RESERVED | OT_WARN_LIMIT[5:0] | |||||
| R-0h | R-0h | R/W-Xh | |||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15:11 | EXPONENT[4:0] | R | 2h | Linear format two's complement exponent. Fixed exponent of 2 resulting in a 4 deg C LSB. |
| 10 | RESERVED | R | 0h | |
| 9 | RESERVED | R | 0h | |
| 8 | RESERVED | R | 0h | |
| 7 | RESERVED | R | 0h | |
| 6 | RESERVED | R | 0h | |
| 5:0 | OT_WARN_LIMIT[5:0] | R/W | X | Linear format mantissa. See the following table for details on the available settings. |