SLVSJC6 December 2025 TPS544B27W
PRODUCTION DATA
TOFF_FALL is shown in Figure 7-45 and described in Table 7-65.
Return to the Summary Table.
Write Transaction: Write Word
Read Transaction: Read Word
Data Format: LINEAR11
NVM Back-up: EEPROM
Updates: On-the-fly The TOFF_FALL command sets the time, in milliseconds, from when a stop condition is received (as programmed by the ON_OFF_CONFIG command) until the output voltage starts to fall. Refer to the OPERATION and ON_OFF_CONFIG command descriptions for details on when the TOFF_FALL period is used upon receiving a stop condition. A combination of the value programmed into this command and the VBOOT value sets the DAC slew rate to achieve the target soft-stop time. Switching stops and the output voltage stops slewing down when the regulated VOUT reaches 0.2V nominal, however the time programmed into this command is based on the output voltage slewing to 0V. As a result the observed TOFF_FALL time to 0V may different than the value programmed into this command, and is dependent on how long it takes the load to discharge the remaining 0.2V output. Data Validity: Attempts to change the read-only bits (TOFF_FALL[15:4]) are considered as invalid data or unsupported data (ivd) and the device responds as described in the IVD bit in STATUS_CML.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| EXPONENT[4:0] | RESERVED | RESERVED | RESERVED | ||||
| R-1Fh | R-0h | R-0h | R-0h | ||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | RESERVED | RESERVED | RESERVED | TOFF_FALL[3:0] | |||
| R-0h | R-0h | R-0h | R-0h | R/W-Xh | |||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15:11 | EXPONENT[4:0] | R | 1Fh | Linear format two's complement exponent. Fixed exponent of -1 resulting in a 0.5ms LSB. |
| 10 | RESERVED | R | 0h | |
| 9 | RESERVED | R | 0h | |
| 8 | RESERVED | R | 0h | |
| 7 | RESERVED | R | 0h | |
| 6 | RESERVED | R | 0h | |
| 5 | RESERVED | R | 0h | |
| 4 | RESERVED | R | 0h | |
| 3:0 | TOFF_FALL[3:0] | R/W | X | Linear format mantissa. These bits select the soft-stop time. Possible values are below. When an unsupported value is written, an adjacent available option will be selected.
|