SLVSJC6 December 2025 TPS544B27W
PRODUCTION DATA
VOUT_DROOP is shown in Figure 7-24 and described in Table 7-31.
Return to the Summary Table.
Write Transaction: N/A
Read Transaction: Read Word
Data Format: Direct (0.1mOhm/LSB)
NVM Back-up: No
Updates: N/A The VOUT_DROOP command sets the rate, in mV/A (mOhm) at which the output voltage decreases with increasing output current for use with adaptive voltage positioning. This may also be referred to as the DC Load Line (DCLL).
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED | RESERVED | RESERVED | RESERVED | RESERVED | RESERVED | RESERVED | RESERVED |
| R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | RESERVED | RESERVED | VOUT_DROOP[4:0] | ||||
| R-0h | R-0h | R-0h | R-0h | ||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15 | RESERVED | R | 0h | |
| 14 | RESERVED | R | 0h | |
| 13 | RESERVED | R | 0h | |
| 12 | RESERVED | R | 0h | |
| 11 | RESERVED | R | 0h | |
| 10 | RESERVED | R | 0h | |
| 9 | RESERVED | R | 0h | |
| 8 | RESERVED | R | 0h | |
| 7 | RESERVED | R | 0h | |
| 6 | RESERVED | R | 0h | |
| 5 | RESERVED | R | 0h | |
| 4:0 | VOUT_DROOP[4:0] | R | 0h | Output voltage droop. This field reflects the active DCLL setting, DCLL_0 or DCLL_1. DCLL_0 or DCLL_1 are selected through PMB_ADDR pinstrap. |