SLVSJC6 December 2025 TPS544B27W
PRODUCTION DATA
VOUT_COMMAND is shown in Figure 7-18 and described in Table 7-21.
Return to the Summary Table.
Write Transaction: Write Word
Read Transaction: Read Word
Data Format: Direct 1mV LSB
NVM Back-up: No
Updates: On-the-fly When the PMBus interface is in control of the output, writes to VOUT_COMMAND cause the device to set its output voltage to the commanded value. Output voltage changes due to VOUT_COMMAND occur at the rate specified by VOUT_TRANSITION_RATE. This command can be written during soft-start or soft-stop. However, the output will continue to ramp up/down to the original target (VBOOT) at the rate programmed into TON_RISE/TOFF_FALL. After soft-start completes (and if VOUT_COMMAND is different from the VBOOT value), the device will immediately transition from the VBOOT value to the latest written VOUT_COMMAND at the programmed VOUT_TRANSITION_RATE. Writes to VOUT_COMMAND during soft-stop will be acknowledged, however, no transition will occur and VOUT_COMMAND will get automatically updated back to VBOOT at the conclusion of soft-stop. During regulation, preemptive writes to VOUT_COMMAND are allowed even if the output is still slewing to a previously programmed VOUT_COMMAND. The device will immediately start slewing to the new target at the rate programmed into VOUT_TRANSITION_RATE.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED | RESERVED | RESERVED | VOUT_COMMAND[12:0] | ||||
| R-0h | R-0h | R-0h | R/W-XXXh | ||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| VOUT_COMMAND[12:0] | |||||||
| R/W-XXXh | |||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15 | RESERVED | R | 0h | |
| 14 | RESERVED | R | 0h | |
| 13 | RESERVED | R | 0h | |
| 12:0 | VOUT_COMMAND[12:0] | R/W | X | The VOUT_COMMAND reset value is determined by VOUT_SCALE_LOOP and VBOOT_0 or VBOOT_1. Note two important details: when writing to VOUT_COMMAND, the LSB does not match the VOUT_MODE setting and instead uses Direct format with a 1mV LSB, and the reset read value uses a 2mV LSB resulting in the device returning half the actual VBOOT voltage value upon a read. After the command is written to, a read of VOUT_COMMAND returns the value written. |