The LM5066Hx output can be disabled during normal operation by pulling the UVLO/EN pin below its threshold or the OVLO pin above its threshold, forcing the GATE voltage low with a pulldown strength of 10mA or 1.5A. Toggling UVLO/EN also resets the device from a latched off state caused by exceeding the maximum retry count during overcurrent or overpower conditions. While UVLO/EN and OVLO pins control output state, they don't affect device memory. User programmed values for address, operation settings, and fault thresholds remain preserved in both operatnig memory and interal EEPROM regardless of these pins states. Output can also be controlled through the PMBus interface by writing 80h (enable) or 0h (disable) to the OPERATION register. After a fault condition, the device can be re-enabled by writing 0h followed by 80h to this register. The POWER_CYCLE command provides controlled output cycling, powering down and then up after a configurable delay set through the RETRY_CONFIG register.