The ALERT_MASK command is used to mask the SMBA when a specific fault or warning has occurred. Each bit corresponds to one of the 16 different analog and digital faults or warnings that would normally result in an SMBA being asserted. When the corresponding bit is high, that condition does not cause the SMBA to be asserted. If that condition occurs, the registers where that condition is captured is still updated (STATUS registers, DIAGNOSTIC_WORD) and the external MOSFET gate control is still active (VIN_OV_FAULT, VIN_UV_FAULT, IIN/PFET_FAULT, CB_FAULT, SCP FAULT, OT_FAULT). This register is accessed with the PMBus read/write word protocol.
Bit | Description | Default |
|---|---|---|
| 15 | VOUT UNDERVOLTAGE WARN | 1 |
| 14 | IIN LIMIT WARN | 1 |
| 13 | VIN UNDERVOLTAGE WARN | 1 |
| 12 | VIN OVERVOLTAGE WARN | 1 |
| 11 | POWER GOOD | 1 |
| 10 | OVERTEMPERATURE WARN | 1 |
| 9 | WATCHDOG FAULT | 0 |
| 8 | OVERPOWER LIMIT WARN | 1 |
| 7 | SCP FAULT | 0 |
| 6 | FET_FAIL FAULT | 0 |
| 5 | VIN UNDERVOLTAGE FAULT | 1 |
| 4 | VIN OVERVOLTAGE FAULT | 0 |
| 3 | IIN/PFET FAULT | 0 |
| 2 | OVERTEMPERATURE FAULT | 0 |
| 1 | CML FAULT (communications fault) | 0 |