SNVSCT1A October 2025 ā December 2025 LM5066H
PRODUCTION DATA
The WD_PLB_ TIMER register is a manufacturer-specific command used to configure the Watch dog timer and Maximum Power Limit Blanking Timer thresholds in the LM5066Hx device. This command uses the PMBus read or write byte protocol.
| Bit | Name | Value | Timer Duration (ms) | Factory Default | EEPROM Default |
|---|---|---|---|---|---|
| 7:4 | WatchDog Timer | 0xFh | 9500 | 0x6Fh | 0xBFh |
| 0xEh | 4750 | ||||
| 0xDh | 2850 | ||||
| 0xCh | 1900 | ||||
| 0xBh | 950 | ||||
| 0xAh | 712.5 | ||||
| 0x9h | 475 | ||||
| 0x8h | 237.5 | ||||
| 0x7h | 190 | ||||
| 0x6h | 142.5 | ||||
| 0x5h | 95 | ||||
| 0x4h | 47.5 | ||||
| 0x3h | 38 | ||||
| 0x2h | 28.5 | ||||
| 0x1h | 19 | ||||
| 0x0h | 9.5 | ||||
| 3:0 | Maximum Power Limit Blanking Timer | 0xFh | 95 | 0xFh | 0xFh |
| 0xEh | 47.5 | ||||
| 0xDh | 19 | ||||
| 0xCh | 9.5 | ||||
| 0xBh | 4.75 | ||||
| 0xAh | 1.9 | ||||
| 0x9h | 0.95 | ||||
| 0x8h | 0.7125 | ||||
| 0x7h | 0.475 | ||||
| 0x6h | 0.38 | ||||
| 0x5h | 0.285 | ||||
| 0x4h | 0.19 | ||||
| 0x3h | 0.095 | ||||
| 0x2h | 0.057 | ||||
| 0x1h | 0.038 | ||||
| 0x0h | 0 |