SNVSCT1A October 2025 – December 2025 LM5066H
PRODUCTION DATA
The READ_AVG_PIN command reports the 12-bit ADC measured VIN x IIN product. The returned value is the default value (0000h) or previous data when the average data is not ready. Average count can be programmed through SAMPLES_FOR_AVG register. The contents of READ_PIN_AVG register can be reset to zero (0x0000h) by setting Bit[6] in the PK_MIN_AVG register high. This data is read with the PMBus read word protocol. This register should use the coefficients shown in Table 7-72.
| Bit | Name | Description | ADC_CONFIG_2 [6] = 0 | ADC_CONFIG_2 [6] = 1 | ||
|---|---|---|---|---|---|---|
Minimum Value | Maximum Value | Minimum Value | Maximum Value | |||
15:0 | READ_PIN_AVG | Value measured for average input power since reset or last clear | 0x0000 (0W) | 0x0FFF (96.23xVCL/RSNS W) | 0x0000 (0W) | 0x0FFF (192.45xVCL/RSNS W) |