SNVSCT1A October 2025 ā December 2025 LM5066H
PRODUCTION DATA
The READ_VIN_PEAK command is a standard PMBus command that returns the 12-bit peak input voltage measured since a power-on reset or the last RESET_PEAK (Bit[7] in the PK_MIN_AVG register) made high. Reading this register should use the coefficients shown in Table 7-72. Accesses to this command should use the PMBus read word protocol.
| Bit | Name | Description | Minimum Value | Maximum Value | Default |
|---|---|---|---|---|---|