Detalles del producto

Vrwm (V) 33 Bi-/uni-directional Bi-directional Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 1100 IEC 61000-4-5 (A) 27 Breakdown voltage (min) (V) 34.4 Number of channels 1 IO capacitance (typ) (pF) 54 Clamping voltage (V) 40
Vrwm (V) 33 Bi-/uni-directional Bi-directional Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 1100 IEC 61000-4-5 (A) 27 Breakdown voltage (min) (V) 34.4 Number of channels 1 IO capacitance (typ) (pF) 54 Clamping voltage (V) 40
VSON (DRB) 8 9 mm² 3 x 3
  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A 8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection
  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A 8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection

The TVS3301 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS3301 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS3301 has a ±33-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS3301 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3301 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS3301 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

The TVS3301 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS3301 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS3301 has a ±33-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS3301 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3301 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS3301 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

Descargar Ver vídeo con transcripción Video

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 14
Tipo Título Fecha
* Data sheet TVS3301 33-V Bidirectional Flat-Clamp Surge Protection Device datasheet (Rev. B) PDF | HTML 01 sep 2022
Circuit design Output Overvoltage Protection Circuit for Voltage DACs With an External Feedback Pin PDF | HTML 29 jul 2025
Circuit design Output Overvoltage Protection Circuit for Voltage DACs Without an External Feedback Pin PDF | HTML 18 jun 2025
Analog Design Journal Designing 4mA to 20mA loop-powered transmitters PDF | HTML 28 may 2024
Analog Design Journal How to use an ideal diode controller as a scalable input bypass switch in solar applications PDF | HTML 28 may 2024
Application note ESD Packaging and Layout Guide (Rev. B) PDF | HTML 18 ago 2022
Functional safety information TVS3301 Functional Safety, FIT Rate, Failure Mode Distribution and Pin FMA PDF | HTML 27 sep 2021
Application brief 16-Bit 8-Channel PLC Analog Input Module with High Voltage (±150 V) Common Mode 27 abr 2020
Application brief Protecting I/O modules from surge events 04 feb 2019
Application brief TVS Surge Rating: Power vs. Current 12 nov 2018
White paper Demystifying surge protection 06 nov 2018
User guide Flat Clamp TVS Evaluation Module—Adaptor Boards 10 sep 2018
Application note How to select a Surge Diode 29 ago 2018
Analog Design Journal Design Considerations for System-Level ESD Circuit Protection 25 sep 2012

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

FLAT-CLAMP-TVS-EVM — Módulo de evaluación TVSxx0x de diodos de protección contra sobretensiones de precisión

El módulo de evaluación de placa adaptadora de diodo de protección contra sobretensiones de exactitud (FLAT-CLAMP-TVS-EVM) demuestra las características, el funcionamiento y el uso de la familia de dispositivos TVSxx0x. La familia de dispositivos TVSxx0x son abrazaderas de exactitud que mantienen (...)
Guía del usuario: PDF
Modelo de simulación

TVS3301 PSpice Transient Model

SLVMCV9.ZIP (52 KB) - PSpice Model
Diseños de referencia

TIDA-010982 — Plataforma de transmisor de campo, diseño de referencia de interfaz con suministro bucle 4mA a 20mA

Este diseño de referencia ofrece un ejemplo de implementación de una interfaz de 4-20 mA para sensores alimentados por bucle de 2 hilos. El diseño permite evaluar los modelos AFE881H1 y AFE882H1 en un entorno similar al de una aplicación de baja potencia con una cadena de señal de 1.8 V. Los (...)
Design guide: PDF
Diseños de referencia

TIDA-010072 — Diseño de referencia de ventilador de aire y control de válvula para aplicaciones respiratorias

Este diseño de referencia proporciona un diseño de sistema compacto capaz de admitir aceleración y deceleración del motor de hasta ±200 kRPM/s, lo que es un requisito clave en muchas aplicaciones de respiradores. El diseño admite varios controladores C2000 externos, incluido el TMS320F28027F, lo (...)
Design guide: PDF
Esquema: PDF
Diseños de referencia

TIDA-010008 — Diseño de referencia basado en supresores de tensión transitoria (TVS) de abrazadera plana para prot

Este diseño de referencia presenta múltiples enfoques para proteger la entrada analógica de CA o CC, la salida analógica de CC, la entrada binaria de CA o CC, la salida digital con un conductor de lado alto o bajo, la alimentación de polarización LCD, las interfaces USB (alimentación y datos) y (...)
Design guide: PDF
Esquema: PDF
Diseños de referencia

TIDA-010044 — Diseño de referencia de entrada digital de PLC NAMUR con diagnóstico y protección contra fallas

El sensor de proximidad NAMUR se utiliza ampliamente en el control industrial cuando el sensor debe cumplir un requisito especial de energía máxima. Esto, a su vez, impone requisitos especiales a la entrada digital de comunicación de línea de alimentación (PLC) diseñada para interactuar con dicho (...)
Design guide: PDF
Esquema: PDF
Encapsulado Pines Símbolos CAD, huellas y modelos 3D
VSON (DRB) 8 Ultra Librarian

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Los productos recomendados pueden tener parámetros, módulos de evaluación o diseños de referencia relacionados con este producto de TI.

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos