Inicio Gestión de la energía AC/DC & DC/DC controllers (external FET)

UCC3895

ACTIVO

Controlador de puente completo con cambio de fase y lógica de control mejorada de 0 °C a 70 °C

Se encuentra disponible una versión más nueva de este producto

open-in-new Comparar alternativas
Misma funcionalidad con diferente configuración de pines que el dispositivo comparado
UCC28951 ACTIVO Controlador de puente completo con cambio de fase ecológica y control SR para un amplio rango de ten SR control, better light load efficiency, and programmable delays for ZVS

Detalles del producto

Vin (max) (V) 16.5 Operating temperature range (°C) 0 to 70 Control mode Current Topology Phase-shifted full bridge Rating Catalog Duty cycle (max) (%) 100
Vin (max) (V) 16.5 Operating temperature range (°C) 0 to 70 Control mode Current Topology Phase-shifted full bridge Rating Catalog Duty cycle (max) (%) 100
PDIP (N) 20 228.702 mm² 24.33 x 9.4 SOIC (DW) 20 131.84 mm² 12.8 x 10.3 TSSOP (PW) 20 41.6 mm² 6.5 x 6.4
  • Programmable-output turnon delay
  • Adaptive delay set
  • Bidirectional oscillator synchronization
  • Voltage-mode, peak current-mode, or average current-mode control
  • Programmable soft start, soft stop, and chip disable via a single pin
  • 0% to 100% duty-cycle control
  • 7-MHz error amplifier
  • Operation to 1 MHz
  • Typical 5-mA operating current at 500 kHz
  • Very low 150-µA current during UVLO
  • Programmable-output turnon delay
  • Adaptive delay set
  • Bidirectional oscillator synchronization
  • Voltage-mode, peak current-mode, or average current-mode control
  • Programmable soft start, soft stop, and chip disable via a single pin
  • 0% to 100% duty-cycle control
  • 7-MHz error amplifier
  • Operation to 1 MHz
  • Typical 5-mA operating current at 500 kHz
  • Very low 150-µA current during UVLO

The UCC3895 is a phase-shift PWM controller that implements control of a full-bridge power stage by phase shifting the switching of one half-bridge with respect to the other. The device allows constant frequency pulse-width modulation in conjunction with resonant zero-voltage switching to provide high efficiency at high frequencies. The part is used either as a voltage-mode or current-mode controller.

While the UCC3895 maintains the functionality of the UC3875/6/7/8 family and UC3879, it improves on that controller family with additional features such as enhanced control logic, adaptive delay set, and shutdown capability. Because the device is built using the BCDMOS process, it operates with dramatically less supply current than it’s bipolar counterparts. The UCC3895 operates with a maximum clock frequency of 1 MHz.

The UCC3895 is a phase-shift PWM controller that implements control of a full-bridge power stage by phase shifting the switching of one half-bridge with respect to the other. The device allows constant frequency pulse-width modulation in conjunction with resonant zero-voltage switching to provide high efficiency at high frequencies. The part is used either as a voltage-mode or current-mode controller.

While the UCC3895 maintains the functionality of the UC3875/6/7/8 family and UC3879, it improves on that controller family with additional features such as enhanced control logic, adaptive delay set, and shutdown capability. Because the device is built using the BCDMOS process, it operates with dramatically less supply current than it’s bipolar counterparts. The UCC3895 operates with a maximum clock frequency of 1 MHz.

Descargar Ver vídeo con transcripción Video

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 15
Tipo Título Fecha
* Data sheet UCCx895 BiCMOS Advanced Phase-Shift PWM Controller datasheet (Rev. Q) PDF | HTML 09 oct 2019
Technical article 35 years later, APEC continues to set the tone for innovation in power management PDF | HTML 27 feb 2020
Selection guide Power Management Guide 2018 (Rev. R) 25 jun 2018
Application note Phase Shifted Full Bridge, Zero Voltage Transition Design Considerations (Rev. A) 22 ene 2011
Application note UCC2895 Layout and Grounding Recommendations 09 abr 2009
EVM User's guide UCC3895EVM-001 Configuring The UCC3895 For Direct Control Driven Synchronous Re (Rev. B) 02 dic 2008
Application note Current Doubler Rectifier Offers Ripple Current Cancellation 21 sep 2004
Application note Synchronous Rectifiers of a Current Doubler 27 feb 2003
Application note UCC3895 CD Output Asymmetric Duty Cycle Operation 21 ago 2002
Application note A Power Management Solution for Efficient, Multiple Output Applications 04 oct 2001
Application note A Comparison Between the BiCMOS UCC3895 Phase Shift Controller and the UC3875 22 feb 2001
More literature Seminar 800 Topic 5 - Fixed-Frequency Resonant-Switched PWM 15 feb 2001
More literature Seminar 900 Topic 3 - Designing a Phase-Shifted ZVT Power Converter 15 feb 2001
More literature Seminar 900 Topic 4 - 500-W 40-W/in3 Phase-Shifted ZVT Power Converter 15 feb 2001
Application note DN-63 The Current-Doubler Rectifier: An Alternative Rectification Technique 12 ene 2001

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

UCC3895EVM-001 — Módulo de evaluación UCC3895

The UCC3895EVM-001 is an isolated 48V input phase shifted full bridge converter providing an output of 3.3V at 15A. Using the AB outputs of the UCC3895, a novel technique for direct control driven synchronous rectification is demonstrated.

Guía del usuario: PDF
Modelo de simulación

UCC1895, UCC2895, UCC3895 TINA-TI Average Reference Design

SLUM188.TSC (99 KB) - TINA-TI Reference Design
Modelo de simulación

UCC1895, UCC2895, UCC3895 TINA-TI Average Spice Model

SLUM189.ZIP (11 KB) - TINA-TI Spice Model
Modelo de simulación

UCC1895, UCC2895, UCC3895 TINA-TI Transient Reference Design

SLUM186.TSC (934 KB) - TINA-TI Reference Design
Modelo de simulación

UCC1895, UCC2895, UCC3895 TINA-TI Transient Spice Model

SLUM187.ZIP (39 KB) - TINA-TI Spice Model
Modelo de simulación

UCCx895 Family PSpice Average Model

SLUM080.ZIP (105 KB) - PSpice Model
Modelo de simulación

UCCx895 and UCCx7324 Families PSpice Transient Model (Rev. A)

SLUM055A.ZIP (90 KB) - PSpice Model
Diseños de referencia

PMP9622 — Diseño de referencia de puente completo con desplazamiento de fase de tensión constante-corriente co

This reference design uses the UCC3895 Phase-Shifted Full Bridge controller to implement a high efficiency, 120VAC input to 44Vdc up to 8A output.  The power supply is set up to be  constant voltage-constant current.  The voltage and current are set by fixed resistor values and could (...)
Test report: PDF
Esquema: PDF
Paquete Pasadores Descargar
PDIP (N) 20 Ver opciones
SOIC (DW) 20 Ver opciones
TSSOP (PW) 20 Ver opciones

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos