SBOSAM2 August 2025 INA701
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
The internal timebase of the device is provided by an internal oscillator that is trimmed to less than 0.5% tolerance at room temperature. The precision oscillator is the timing source for ADC conversions, as well as the time-count used for calculation of energy and charge. The digital filter response varies with conversion time; therefore, the precise clock provides filter response and notch frequency consistency across temperature. On power up, the internal oscillator and ADC take roughly 300µs to reach <1% error stability. After the clock stabilizes, the ADC data output is accurate to the electrical specifications provided in Specifications.