SBASAW5 December   2025 ADS112C14 , ADS122C14

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Pin Configuration and Functions
  6. 5 Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 I2C Timing Requirements
    7. 5.7 I2C Switching Characteristics
    8. 5.8 Timing Diagrams
    9. 5.9 Typical Characteristics
  7. 6 Parameter Measurement Information
    1. 6.1 Noise Performance
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Analog Inputs and Multiplexer
      2. 7.3.2  Programmable Gain Amplifier (PGA)
      3. 7.3.3  Voltage Reference
        1. 7.3.3.1 Internal Reference
        2. 7.3.3.2 External Reference
        3. 7.3.3.3 Reference Buffers
      4. 7.3.4  Clock Source
      5. 7.3.5  Delta-Sigma Modulator
      6. 7.3.6  Digital Filter
        1. 7.3.6.1 Sinc4 and Sinc4 + Sinc1 Filter
        2. 7.3.6.2 FIR Filter
        3. 7.3.6.3 Digital Filter Latency
        4. 7.3.6.4 Global-Chop Mode
      7. 7.3.7  Excitation Current Sources (IDACs)
      8. 7.3.8  Burn-Out Current Sources (BOCS)
      9. 7.3.9  General Purpose IOs (GPIOs)
        1. 7.3.9.1 FAULT Output
        2. 7.3.9.2 DRDY Output
      10. 7.3.10 System Monitors
        1. 7.3.10.1 Internal Short (Offset Calibration)
        2. 7.3.10.2 Internal Temperature Sensor
        3. 7.3.10.3 External Reference Voltage Readback
        4. 7.3.10.4 Power-Supply Readback
      11. 7.3.11 Monitors and Status Flags
        1. 7.3.11.1 Reset (RESETn flag)
        2. 7.3.11.2 AVDD Undervoltage Monitor (AVDD_UVn flag)
        3. 7.3.11.3 Reference Undervoltage Monitor (REV_UVn flag)
        4. 7.3.11.4 Register Map CRC Fault (REG_MAP_CRC_FAULTn flag)
        5. 7.3.11.5 Internal Memory Fault (MEM_FAULTn flag)
        6. 7.3.11.6 Register Write Fault (REG_WRITE_FAULTn flag)
        7. 7.3.11.7 DRDY Indicator (DRDY bit)
        8. 7.3.11.8 Conversion Counter (CONV_COUNT[3:0])
    4. 7.4 Device Functional Modes
      1. 7.4.1 Power-up and Reset
        1. 7.4.1.1 Power-On Reset (POR)
        2. 7.4.1.2 Reset by Register Write
        3. 7.4.1.3 I2C General Call Reset
      2. 7.4.2 Operating Modes
        1. 7.4.2.1 Idle and Standby Mode
        2. 7.4.2.2 Power-Down Mode
        3. 7.4.2.3 Power-Scalable Conversion Modes
          1. 7.4.2.3.1 Continuous-Conversion Mode
          2. 7.4.2.3.2 Single-shot Conversion Mode
    5. 7.5 Programming
      1. 7.5.1  I2C Interface
      2. 7.5.2  I2C Address
      3. 7.5.3  Serial Clock (SCL) and Serial Data (SDA)
      4. 7.5.4  I2C Bus Speed
      5. 7.5.5  I2C Data Transfer Protocol
      6. 7.5.6  I2C General Call (Software Reset)
      7. 7.5.7  I3C Compatibility
      8. 7.5.8  Commands
        1. 7.5.8.1 RDATA (0000 0000b)
        2. 7.5.8.2 RREG (0100 rrrrb)
        3. 7.5.8.3 WREG (1000 rrrrb)
      9. 7.5.9  STATUS Header
      10. 7.5.10 I2C CRC
      11. 7.5.11 Register Map CRC
      12. 7.5.12 Data Ready (DRDY) Pin
      13. 7.5.13 Monitoring for New Conversion Data
        1. 7.5.13.1 DRDY Pin Monitoring
        2. 7.5.13.2 Reading DRDY Bit and Conversion Counter
        3. 7.5.13.3 Clock Counting
      14. 7.5.14 Conversion Data Format
  9. 8 Registers
  10. 9 Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Serial Interface Connections
      2. 9.1.2 Connecting Multiple Devices on the Same I2C Bus
      3. 9.1.3 Unused Inputs and Outputs
      4. 9.1.4 Device Initialization
    2. 9.2 Typical Applications
      1. 9.2.1 Software-Configurable RTD Measurement Input
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Performance Plots
        4. 9.2.1.4 Design Variant – 3-Wire RTD Measurement With Automatic Lead-Wire Compensation Using Two IDACs
      2. 9.2.2 Thermocouple Measurement With Cold-Junction Compensation Using a 2-wire RTD
      3. 9.2.3 Resistive Bridge Sensor Measurement With Temperature Compensation
    3. 9.3 Power Supply Recommendations
      1. 9.3.1 Power Supplies
      2. 9.3.2 Power-Supply Sequencing
      3. 9.3.3 Power-Supply Decoupling
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information
Continuous-Conversion Mode

In continuous-conversion mode, the ADC converts indefinitely until stopped by the user. Set the START bit to 1b to start conversions. Setting the START bit to 1b while conversions are ongoing aborts the ongoing conversion and restarts conversions.

Use the STOP bit to stop conversions. The currently ongoing conversion is allowed to finish after the STOP bit is set to 1b. After setting the STOP bit, the STOP bit reads back 1b until conversions are stopped. When conversions stopped, the STOP bit reads back 0b to indicate the device transitioned to idle or standby mode.

Writing 1b to both the START and STOP bits at the same time has no effect.

The last conversion result is still available for readout after conversions stopped. The conversion results only clear after a device reset, in power-down mode, or are overwritten when a new conversion result becomes available.

The START bit takes effect at the rising SCL edge of the ACK bit after the CONVERSION_CTRL register is written.

If DRDY is low, setting the START bit drives the DRDY pin high, however the old conversion data can still be read until the new conversions become available.

When conversions are started or restarted using the START bit, the device hides unsettled conversions and only provides a settled conversion result after the conversion latency period (tLATENCY) plus the optional delay time (tDELAY) as shown in Digital Filter Settling Time and Conversion Period. All subsequent conversions have a conversion period of tDATA = 1 / fDATA = OSR / fMOD.

ADS112C14 ADS122C14 Digital Filter Settling Time
                    and Conversion Period Figure 7-14 Digital Filter Settling Time and Conversion Period