SLOS970B January 2018 – January 2025 TPA6404-Q1
PRODUCTION DATA
The Warning PIN Control register is shown in Figure 8-28 and described in Table 8-29.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | OT_FAULT_LATCH_ENABLE | I_LIMIT_STATUS_LATCH_ENABLE | DVDD_UV_LATCH_ENABLE | POR_LATCH_EN | OTW_LATCH_EN | I_LIMIT_WARNING_LATCH_EN | CLIP_WARNING_LATCH_ENABLE |
| R | R/W | R/W | R/W | R/W | R/W | R/W | R/W |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | RESERVED | R | 0 | |
| 6 | OT_FAULT_LATCH_ENABLE | R/W | 1 | 0: Disable Latching of Over Temperature Report on FAULT pin 1: Enable Latching of Over Temperature Report on FAULT pin |
| 5 | I_LIMIT_STATUS_LATCH_ENABLE | R/W | 1 | 0: Disable Latching of Current Limit Fault report on FAULT pin 1: Enable Latching of Current Limit Fault report on FAULT pin |
| 4 | DVDD_UV_LATCH_ENABLE | R/W | 1 | 0: Disable Latching of DVDD Under Voltage Reporting on WARN pin 1: Enable latching of DVDD Under Voltage Report on WARN pin |
| 3 | POR_LATCH_EN | R/W | 1 | 0: Disable Latching of DVDD POR Report on WARN pin 1: Enable Latching of DVDD POR Report on WARN pin |
| 2 | OTW_LATCH_EN | R/W | 1 | 0: Disable Latching of Over Temperature Warning Reporting on WARN pin 1: Enable Latching of Over Temperature Warning Report on WARN pin |
| 1 | I_LIMIT_WARNING_LATCH_EN | R/W | 1 | 0: Disable Latching of Current Limit Warning Reporting on WARN pin 1: Enable Latching of Current Limit Warning Report on WARN pin |
| 0 | CLIP_WARNING_LATCH_ENABLE | R/W | 1 | 0: Disable pin latching of CLIP Reporting 1: Enable pin latching of CLIP Reporting |