SLOS970B January 2018 – January 2025 TPA6404-Q1
PRODUCTION DATA
The device incorporates both DC- and AC-load diagnostics which are used to determine the status of the load. The DC-diagnostics are turned on by default. However, if a fast startup without diagnostics is required, the diagnostics can be bypassed through I2C. The DC-diagnostics run when any channel is directed to leave the Hi-Z state and enter the MUTE or PLAY state. The diagnostics can also be enabled manually to run on any or all channels even if the other channels are playing audio. Diagnostics can be started from any operating condition, but if the channel is in PLAY state then the time to complete the diagnostic is longer because the device must go to the Hi-Z state. The diagnostics are available as soon as the device supplies are within the recommended operating range. The diagnostics do not rely on the audio input signals or sync frequency to be available to function since the internal oscillator is used for the diagnostic block. Diagnostic results are reported for each channel separately through the I2C registers.