The AC Load Diagnostic Report Ch1 through CH4 registers are shown in Figure 8-19 and described in Table 8-20.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CHx IMPEDANCE | |||||||
| R | |||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7–0 | CHx IMPEDANCE | R | 00000000 | 8 bit AC load diagnostic impedance report for each channel. See Table 7-3 for impedance calculation 0x00: 0 Ω 0x01: 0.059 Ω ... 0xFF: 15.045 Ω |