The Current Limit Status register is shown in Figure 8-27 and described in Table 8-28.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CH4 I-LIMIT_FAULT | CH3 I-LIM_FLT | CH2 I-LIM_FLT | CH1 I-LIM_FLT | CH4_I_LIM_WN | CH3_I_LIM_WN | CH2_I_LIM_WN | CH1_I_LIM_WN |
| R | R | R | R | R | R | R | R |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | CH4_I_LIMIT_FAULT | R | 0 | 0: No Current Limit Fault 1: Current Limit Fault |
| 6 | CH3_I_LIMIT_FAULT | R | 0 | 0: No Current Limit Fault 1: Current Limit Fault |
| 5 | CH2_I_LIMIT_FAULT | R | 0 | 0: No Current Limit Fault 1: Current Limit Fault |
| 4 | CH1_I_LIMIT_FAULT | R | 0 | 0: Current Limit Fault 1: Current Limit Fault |
| 3 | CH4_I_LIMIT_WARN | R | 0 | 0: No Current Limit Warning 1: Current Limit Warning |
| 2 | CH3_I_LIMIT_WARN | R | 0 | 0: No Current Limit Warning 1: Current Limit Warning |
| 1 | CH2_I_LIMIT_WARN | R | 0 | 0: No Current Limit Warning 1: Current Limit Warning |
| 0 | CH1_I_LIMIT_WARN | R | 0 | 0: No Current Limit Warning 1: Current Limit Warning |