SLOS970B January 2018 – January 2025 TPA6404-Q1
PRODUCTION DATA
The DC Load Diagnostic Report, Line Output, register is shown in Figure 8-10 and described in Table 8-11.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | CH1 LO LDG | CH2 LO LDG | CH3 LO LDG | CH4 LO LDG | |||
| R | R | R | R | R | R | R | R |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7–4 | RESERVED | R | 0000 | |
| 3 | CH1 LO LDG | R | 0 | 0: No line output detected on channel 1 1: Line output detected on channel 1 |
| 2 | CH2 LO LDG | R | 0 | 0: No line output detected on channel 2 1: Line output detected on channel 2 |
| 1 | CH3 LO LDG | R | 0 | 0: No line output detected on channel 3 1: Line output detected on channel 3 |
| 0 | CH4 LO LDG | R | 0 | 0: No line output detected on channel 4 1: Line output detected on channel 3 |