SLOS970B January 2018 – January 2025 TPA6404-Q1
PRODUCTION DATA
The Thermal Foldback Control register is shown in Figure 8-29 and described in Table 8-30.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| ZC_WAIT_TIME | BYPASS | ZC_BYPASS | ATTACK | RELEASE | |||
| R/W | R/W | R/W | R/W | R/W | R/W | R/W | R/W |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7-6 | ZC_WAIT_TIME | R/W | 00 | 00: 20 µS System waits this period for Zero Crossing, then changes gain regardless. 01: 80 µS 10: 320 µS 11: 1280 µS |
| 5 | BYPASS | R/W | 0 | 0: Enable Thermal Foldback 1: Disable Thermal Foldback |
| 4 | ZC_BYPASS | R/W | 0 | 0: Enable Zero Crossing detection 1: Disable Zero Crossing detection. Gain changes as soon as thermal condition is met without waiting for zero detection. |
| 3-2 | ATTACK | R/W | 00 | 00: 1dB/100 mS 01: 1dB/ 200 mS 10: 1dB/400 mS 11: 1dB/ 800 mS |
| 1-0 | RELEASE | R/W | 00 | 00: 1dB/200 mS 01: 1dB/400 mS 10:1dB/800 mS 11: 1dB/1600 mS |