SLOS970B January 2018 – January 2025 TPA6404-Q1
PRODUCTION DATA
The AC Load Diagnostic Control 1 register is shown in Figure 8-17 and described in Table 8-18.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CH1/2 GAIN | RESERVED | CH3/4 GAIN | RESERVED | CH1 ENABLE | CH2 ENABLE | CH3 ENABLE | CH4 ENABLE |
| R/W | R | R/W | R | R/W | R/W | R/W | R/W |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | CH1 and CH2 GAIN | R/W | 0 | 0: Gain 1 1: Gain 4 |
| 6 | RESERVED | R | 0 | |
| 5 | CH3 and CH4 GAIN | R/W | 0 | 0: Gain 1 1: Gain 4 |
| 4 | RESERVED | R | 0 | |
| 3 | CH1 ENABLE | R/W | 0 | 0: AC diagnostics disabled 1: Enable AC diagnostics |
| 2 | CH2 ENABLE | R/W | 0 | 0: AC diagnostics disabled 1: Enable AC diagnostics |
| 1 | CH3 ENABLE | R/W | 0 | 0: AC diagnostics disabled 1: Enable AC diagnostics |
| 0 | CH4 ENABLE | R/W | 0 | 0: AC diagnostics disabled 1: Enable AC diagnostics |